HOLMARC’s New 125mm & 150mm focal length CT monochromators are compact mini optical system delivering a high performance, reliable solution wide scan wavelength measurement over UV-VIS-IR region (185nm - 3300nm). Its features are comparable to many larger, more expensive, conventional models. At just 16 x 8cm the 125F5 monochromator (20 x 10cm for 150mm F6 monochromator) features a compact design with a single entrance and exit slit with up to two diffraction gratings ideal for accommodation into the smallest of spaces available, particularly suitable in OEM applications.
The 150F6 monochromator is ideally suited to measurements whereby a medium to lower spectral resolution is required, i.e. as tuneable light source, wavelength scan measurement system etc. Suitable for integration into a larger measurement system. Because of the compact design it can be used in a variety of sophisticated analytical and biomedical equipment such as: clinical chemistry analyzers, HPLC detectors, and UV-VIS-NIR spectrophotometers.
Optical Layout | : | Czerny Turner |
Focal length | : | 120, 125 & 150mm |
Grating mount | : | Single / Dual grating turret |
Number of gratings | : | 1 - 2 |
Grating size | : | 25 x 25 mm |
Aperture ratio | : | f/4, f/5 & f/6 |
Number of entrance / exit ports | : | 1 |
Fiber optic coupler plate | : | Yes, converts slit aperture to SMA connector |
Mechanical resolution drive | : | 0.000072°/ step |
Slit type | : | Fixed, Micrometer or motorized |
Slit width | : | 10 μm - 2 mm |
Slit height | : | 12 mm |
Higher order filter size | : | 12.5 mm |
Linear dispersion | : | 3.9 nm / mm (150 mm f) |
Wavelength accuracy | : | ± 0.25 nm |
Computer interface | : | USB 2.0 |
Software control | : | Holmarc Spectra Scan |
Can be held in any position vertical or horizontal |
Provision to screw a rectangular to round fibre patch cord on both input and output slit |
Computer control of monochromator with QSR software (Lab View support) |
Model | Wavelength Range | f # | Grating | Resolution Typical Operation |
HO-SP-120F4-M1 | 350 - 1100 nm | f 4 | Single, 1200 l/mm | 1.25 nm |
HO-SP-125F5-M1A | 190 - 1100 nm | f 5 | Single, 800 l/mm | 1.75 nm |
HO-SP-125F5-M1B | 190 - 900 nm | f 5 | Single, 1200 l/mm | 1.2 nm |
HO-SP-125F5-M1C | 350 - 700 nm | f 5 | Single, 2400 l/mm | 0.65 nm |
HO-SP-150F6-M1A | 190 - 1100 nm | f 6 | Single, 800 l/mm | 1.5 nm |
HO-SP-150F6-M1B | 190 - 900 nm | f 6 | Single, 1200 l/mm | 1 nm |
HO-SP-150F6-M1C | 350 - 700 nm | f 6 | Single, 2400 l/mm | 0.5 nm |
HO-SP-150F6-M2A | 190 - 1100 nm | f 6 | Dual, 1200 & 2400 l/mm | 0.5 nm |
HO-SP-150F6-M2B | 190 - 1600 nm | f 6 | Dual, 800 & 1200 l/mm | 1 nm |
HO-SP-150F6-M2C | 1000 - 3300 nm | f 6 | Dual, 800 & 600 l/mm | 1.5 nm |
HOLMARC’s MMS-125F5 hand held Mini Monochromator is a manually operated light weight monochromator size of that utilizes a knob dial and a precision linear engraved top for wavelength selection. For quick wavelength selection a quick release lever also provided. Precision lead screw sine bar mechanism is used for the rotation of the diffraction grating which positions the selected wavelength at the exit slit. Wavelength can be read directly in nanometers from engraved top.
These are ideal choice for compact wavelength selection system. 0-5 mm micrometer controlled variable slit is used for the wavelength band width controls. Narrower slits increase resolution but decrease throughput. Wider slits increase throughput at the expense of spectral purity.
# Note: It is possible to converts slit aperture to SMA connector.
Optical Layout | : | Czerny Turner |
Focal length | : | 125 & 100mm |
Grating mount | : | Single |
Grating size | : | 25 x 25 mm |
Aperture ratio | : | f/5 & f/4 |
Number of entrance / exit ports : 1 | ||
Fiber optic coupler plate : Yes, converts slit aperture to SMA connector |
Mechanical resolution drive | : | 0.000072°/ step |
Slit type | : | Fixed |
Slit width | : | 10 μm - 3 mm |
Slit height | : | 12 mm |
Higher order selection | : | Manual |
Higher order filter size | : | 12.5 mm |
Model | Wavelength Range | f # | Grating | Resolution Typical Operation |
HO-SP-125F5-MM1A | 190 - 1100 nm | f 5 | Single, 800 l/mm | 1.75 nm |
HO-SP-125F5-MM1B | 190 - 900 nm | f 5 | Single, 1200 l/mm | 1.2 nm |
HO-SP-125F5-MM1C | 350 - 700 nm | f 5 | Single, 2400 l/mm | 0.75 nm |
HO-SP-100F4-MM2A | 190 - 1100 nm | f 4 | Single, 800 l/mm | 2 nm |
HO-SP-100F4-MM2B | 190 - 900 nm | f 4 | Single, 1200 l/mm | 1.5 nm |
HO-SP-100F4-MM2C | 350 - 700 nm | f 4 | Single, 2400 l/mm | 1 nm |
Home | Products | Supports | Company | Contact Us
|